SMLC V2 Hardware

SMLC Revision 2.0 Hardware

SMLC hardware Revision 2.0 introduced locking 1394 connectors for the ultimate in reliability. SMLC hardware Rev. 2 includes three 1394 connectors on the SMLC-160 to simplify the topology of a ServoWire drive network as the number of axes increases. Note that SMLC revision 2.0 hardware requires SMLC firmware v2.6 or later.  SMLC firmware v2.6 is available to all registered users in the SMLC software section of the Support Library. In addition to the frequently asked questions (FAQs), consult this guide to replacing SMLC hardware.

SMLC v2 hardware, front view, with locking cable callout

Comparison of SMLC rev1.x and rev2.0 hardware

The figure below shows the differences between rev1.x and rev2.0 SMLC hardware

Hardware comparison

SMLC hardware revision is indicated by the product label on the left side of the unit. The revision field in the picture below indicates 2.0.00. In SMLC hardware rev2, the serial number suffix is greater than 200. In SMLC hardware rev1, the serial number suffix is between 100 and 200.

SMLC product label

SMLC Product Label

If you have questions about this revision that are not answered by the FAQ on the right, please contact ORMEC support at (585) 385-3520 or via e-mail at support@ormec.com

  
SMLC2 Hardware

When I replace an existing rev1 SMLC, do I need to change any wiring?

Perhaps. If the rev1 SMLC used any local analog and/or digital I/O on the J18 connecto, these connections have been split and relocated onto two separate terminal blocks. The DC power for the digital I/O is now on the front of the unit (TB1) and the analog I/O has moved to the top of the SMLC (TB2). You do not need to replace the existing 1394 cables with the new locking cables, the "old" cables will work in the new locking ports.